IBT Power Limited
www.ibt-power.com
 

   

  

IBT Product List

Valve Regulated Lead Acid Battery Range

LEAD ACID BATTERY PRODUCT LIST

IBT offer a wide range of valve regulated lead acid batteries for all different types of applications including: Access / Intruder Alarm Control Panels, Communications, Medical, Transport , Industrial, Telecommunications, Leisure and Mobility.

LEAD ACID BATTERIES

Series Features
 BT The IBT BT valve regulated lead acid battery range have a typical design life of 5 years. They are similar in design to the general purpose BT-M batteries but have terminal posts place of the threaded terminal inserts found on the BT-M series. Products in this range are 2V, 4V, 6V, 12V and 24V monoblocks and battery / cell capacities start at 0.5Ah and finish at 200Ah. These batteries are commonly used in standby systems, Uninterruptible Power Supplies (UPS), portable equipment and fire & secuity panels.
BT Valve Regulated Lead Acid Batteries
 BT-M General purpose valve regulated lead acid battery range general purpose with threaded terminal inserts & 5 year design life. Capacities from 17 to 200Ah
Valve regulated lead acid batteries deisgned for portable equipment and medial instruments. Capacities: 2 to 8Ah.
 BT-HR The BT-HR valve regulated lead acid battery range has a typical design life of 3 - 5 years. They are supplied with Faston tabs or terminal posts . All products in this range are 6V or 12V monoblocks and battery capacities start at 5Ah and finish at 18Ah. These batteries are commonly used in standby systems and Uninterruptible Power Supplies (UPS) where higher power is required for shorter periods (less than an hour).
BT-HR High Rate Lead Acid Batteries
 BT-UPS The IBT BT-UPS valve regulated lead acid battery range has a typical design life of 8 - 10 years. They are supplied with terminal posts as standard, however threaded terminal inserts are available as an option. All products in this range are 12V monoblocks and battery capacities start at 26Ah and finish at 200Ah. These batteries are commonly used in standby systems and Uninterruptible Power Supplies (UPS) where higher power is required for shorter periods (less than an hour).
BT-HR High Rate Lead Acid Batteries
 BT-HC The IBT BT-HC cyclic, valve regulated lead acid battery range has been designed for applications which require constant charge / discharge cycles. They are supplied with terminal posts as standard, however threaded terminal inserts are available as an option on some models. Products in this range are 6V, 12V, 24V or 36V monoblocks and battery capacities start at 5Ah and finish at 200Ah. These batteries are commonly used in mobility, leisure and medical applications.
Gel Lead acid Batteries
 BT-GEL The IBT BT-GEL valve regulated lead acid battery range has been designed for applications which have more frequent cycles than standby applications. A Gel electrolyte is used to offer increased deep discharge recovery peformance. They are supplied with Faston tabs or terminal posts as standard, however threaded terminal inserts are available as an option on some models. Products in this range are either 6V or 12Vmonoblocks and battery capacities start at 1.3Ah and finish at 200Ah. These batteries are commonly used in cable, communication and medical applications.
Gel Lead Acid Batteries
  BT - UXL The IBT BT-UXL high integrity, valve regulated lead acid battery range has a typical design life of 10 - 12 years. They are supplied with terminal posts as standard, however threaded terminal inserts are available as an option. All products in this range are either 6V or 12V monoblocks and battery capacities start at 40Ah and finish at 200Ah. These batteries are commonly used in standby systems and Uninterruptible Power Supplies (UPS) in industrial, renewable energy and telecoms applications.
UXL High Inegrity Lead Acid Batteries
 FT The IBT BT-FT stationary, high integrity, valve regulated lead acid battery range have a typical design life of 12 years. They have thier threaded insert terminals located at the front for easy maintenance when mounted on battery racks or in enclosures. Flame Retardant Cases are optional. Products in this range are 12V monoblocks and battery capacities start at 50Ah and finish at 170Ah. These batteries are commonly used in standby systems, Uninterruptible Power Supplies (UPS) and 48V Telecom systems.
FT High Inegrity Lead Acid Batteries
 BTS-JS The IBT BT-JS stationary, high integrity, valve regulated lead acid battery range have a typical design life of 10 -15 years. They have exceptional deep discharge recovery peformance and have a Non-Spillable construction design. Flame Retardant Cases are optional. Products in this range are 2V monoblocks and cell capacities start at 100Ah and finish at 1000Ah. These batteries are commonly used in standby systems, rail transport, renewable energy and communication systems.
BTS-JS Stationary Lead Acid Batteries
Series Features

 
  

  
Copyright © 2001-2017 IBT Power Limited